Abstract
When subjected to alternating stresses, most materials degrade, e.g., suffer premature failure, due to a phenomenon known as fatigue. It is generally accepted that in brittle materials, such as ceramics, can only take place in toughened solids, i.e., premature failure would not be expected in materials such as single crystal silicon. The results of this study, however, appear to be at odds with the current understanding of brittle material fatigue. Twelve thin-film (/spl sim/20 /spl mu/m thick) single crystal silicon specimens were tested to failure in a controlled air environment (30/spl plusmn/0.1/spl deg/C, 50/spl plusmn/2% relative humidity). Damage accumulation and failure of the notched cantilever beams were monitored electrically during the fatigue test. Specimen lives ranged from about 10 s to 48 days, or 1/spl times/106 to 1/spl times/1011 cycles before failure over stress amplitudes ranging from approximately 4 to 10 GPa. A variety of mechanisms are discussed in light of the life data and fracture surface evaluation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Journal of Microelectromechanical Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.