Abstract
A great number of interruption experiments were made in a vacuum chamber with the contact materials Cu, CuCr (50/50) and AgWC. The currents to be interrupted varied from 2.5 to 32 kA. The rate of change of current and recovery voltage were kept at a fixed value immediately after current zero. Many reignitions of the dielectric type were observed but only a few of the thermal type. No evidence of strong anode spot melting was found. At 5 to 10 /spl mu/s after post arc current, a second post arc current also appeared.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.