Abstract

In this study, different concentrations of PAC combined with MBR were carried out to treat slightly polluted surface water (SPSW) at low temperature (10°C). Effects of PAC on the efficiencies of operation, treatment, and the performance of the process were investigated. It was found that the effluent quality, performance efficiency, resistance of shock load were all enhanced and chemical irreversible membrane fouling was reduced with increasing dosage of PAC in MBR. Only when the concentration of PAC which acted as biological carriers was high enough (i.g., 50g/L), nitrification without initial inoculation in the filtration tank could start within 19days and be completed within 35days at 10°C. Fifty grams per liter PAC was the optimal dosage in MBR for stable and extended operation. Under this condition, mean removal efficiencies of ammonia nitrogen (NH3-N), dissolved organic carbon (DOC) and UV254 were 93%, 75%, and 85%, respectively.