Abstract

The signal and noise of single-layer Co/sub 79/Cr/sub 21/ media are measured with ring heads to estimate the area density that can be achieved. Densities as high as 100 Mb/cm/sup 2/ (1 mu m/sup 2//bit) are expected when a signal-to-noise ratio sufficient for an error probability less than 10/sup -5/ is required. As a comparison, densities estimated from data from metal-evaporated tape and CrO/sub 2/ tape are given. In the frequency response of the single-layer media, an additional minimum was observed for a wavelength slightly larger than the gap length. This is probably caused by the bipolar nature of the perpendicular recording field of a ring head.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>