Abstract

DWI using a standard b-value of 1000 s/mm(2) has emerged as the most sensitive sequence for the diagnosis of CJD. The purpose of this study was to investigate whether DWI at a high b-value (b = 3000 s/mm(2)) and ADC measurements in the basal nuclei improve the diagnosis of vCJD and sCJD compared with visual assessment of DWI at a standard b-value (b = 1000 s/mm(2)). Eight patients with vCJD, 9 patients with sCJD, and 5 healthy volunteers underwent DWI at b = 1000 s/mm(2), and 5 vCJD patients, 4 sCJD patients, and 1 growth hormone-related CJD patient underwent DWI at b = 3000 s/mm(2). Two consultant neuroradiologists performed a visual comparison of the b = 1000 and b = 3000 images. Mean MR SI and ADC values were determined for C, P, and DM thalamus ROIs bilaterally at each b-value. SI ratios for each ROI relative to white matter were calculated. In 9 out of 10 patients, the higher b-value images were more sensitive to SI change, particularly in cortex and thalamus, with higher SI ratios at b = 3000 in the DM thalamus. For sCJD at b = 1000, we found significantly lower ADC values in the C and P compared with controls (mean C ADC = 587.3 +/- 84.7 mm(2)/s in sCJD patients versus 722.7 +/- 16.6 mm(2)/s in controls; P = .007), and at b = 3000, the differences were more pronounced. In comparison, in vCJD at b = 1000, ADC values were elevated in the Pu (mean Pu ADC = 837.6 +/- 33.0 mm/s(2) in vCJD patients versus 748.0 +/- 17.3 mm/s(2) in controls; P < .001) but failed to reach significance at b = 3000. Our results demonstrate that b = 3000 DWI, being more sensitive to slowly diffusing tissue water, is more sensitive to pathology in sCJD than is conventional DWI. High-b-value DWI increases confidence in the radiologic diagnosis of human prion disease.

Highlights

  • ObjectivesThe purpose of this study was to investigate whether DWI at a high b-value (b ϭ 3000 s/mm2) and ADC measurements in the basal nuclei improve the diagnosis of vCJD and sCJD compared with visual assessment of DWI at a standard b-value (b ϭ 1000 s/mm)

  • AND PURPOSE: DWI using a standard b-value of 1000s/mm[2] has emerged as the most sensitive sequence for the diagnosis of CJD

  • For sCJD at b ϭ 1000, we found significantly lower ADC values in the C and P compared with controls, and at b ϭ 3000, the differences were more pronounced

Read more

Summary

Objectives

The purpose of this study was to investigate whether DWI at a high b-value (b ϭ 3000 s/mm2) and ADC measurements in the basal nuclei improve the diagnosis of vCJD and sCJD compared with visual assessment of DWI at a standard b-value (b ϭ 1000 s/mm). The purpose of this study was to investigate whether DWI at high

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.