High-resolution mass flux measurements of an electrospray plume are reported at high (>30^{circ }) angles, which are relevant to direct impingement of downstream electrodes. Interrogation of the plume edge greatly reduces uncertainty in electrospray device lifetime estimation related to mass flux to electrode surfaces. An angularly-actuated Thermoelectric Quartz Crystal Microbalance (TQCM) provides resolution down to sim2 pg cm^{-2} s^{-1}, allowing the highest resolution mass flux measurements of an electrospray plume to be reported herein. In-situ microscopy of the electrospray meniscus revealed changes to the electrode lines-of-sight of approximately 2°–3° due to the increasing meniscus tip height with beam current. Using the TQCM measurements and previous QCM results, a data-driven model is proposed for estimating electrode impingement as a function of beam current and aperture line-of-sight, which quantitatively captures the rapid increase in mass flux at higher beam currents or at low angles. The results show it is possible to guarantee negligible electrode impingement within a specified range of throttle levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.