Abstract
A low frequency testing technology based on eddy current technique is proposed for detecting defects in some special equipment surface. A two-dimension model is built to simulate the distribution of low frequency (10 Hz) magnetic flux density nearby the surface of a metal plate. The influence of lift-off effect, coil diameter, crack shape on the measurement are discussed. And the crack measurement sensitivity of 0.6 pm was obtained.