Abstract

The present study aims to diagnose malignant pleural effusion (MPE) based on the identification of distinctive Raman spectra bands. The tests on 83 pleural effusion (PE) samples including 32 benign PE (BPE) and 51 MPE were performed based on rapid and label-free surface-enhanced Raman spectroscopy (SERS). The TiO2 photo-catalyzed Ag NPs were used as SERS substrate. And the SERS spectra of BPE and MPE were compared and diagnosed through orthogonal partial least squares discriminant analysis (OPLS-DA). The diagnosis results showed that the sensitivity and specificity can reach 92.2% and 93.8%, respectively, based on leave-one-out cross validation. And the area under curve values of MPE was 0.985. This study demonstrated an accurate way of combining Raman spectra of PE with OPLS-DA to identify MPE and BPE.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.