Abstract

The State of California released a draft maximum contaminant level (MCL) for hexavalent chromium [Cr(VI)] of 10 μg/L, which is five times lower than the current California total chromium (Cr) MCL. Cr(VI) and total Cr are covered by the Unregulated Contaminant Monitoring Rule 3 (UCMR3), with potential federal regulation on the horizon. The City of Glendale, Calif., in partnership with other entities, completed a decade of research identifying, testing, and implementing treatment technology options for removing Cr(VI) to low microgram‐per‐litre levels, including weak‐base anion (WBA) exchange, reduction/coagulation/filtration (RCF), and strong‐base anion (SBA) exchange. Demonstration‐scale testing of WBA at 425 gpm and RCF at 100 gpm for more than two years proved the effectiveness of the technologies at achieving < 1 μg/L Cr(VI) in treated water. Primary considerations in technology selection include disposal options for residuals, water quality, operational staff training, footprint, and cost.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.