Abstract

PurposeThe standard radiotherapy regimen for small cell lung cancer (SCLC) was determined using dose calculations without corrections for tissue heterogeneity, while modern treatments are planned using algorithms accounting for tissue heterogeneity. We assessed differences in dose delivered using heterogeneous and homogeneous dose calculations in a cohort of patients treated for limited-stage small cell lung cancer (LS-SCLC).MethodsThis is a retrospective analysis of 35 patients (three-dimensional conformal radiation therapy (3D-CRT), n = 22; intensity-modulated radiation therapy (IMRT), n = 13) with LS-SCLC treated with chemoradiotherapy from 2011 to 2017. Treatment plans were developed in the Eclipse Treatment Planning System (TPS) version 13.6 using the Analytical Anisotropic Algorithm (AAA). Two plans were generated for each patient with one using the unit relative electron density and the other maintaining the same monitor units (MUs) with tissue density corrections. The prescription was 45 Gy in 30 fractions of 1.5 Gy delivered twice daily. Individuals who underwent replanning within the same treatment course were evaluated using a separate corrected and uncorrected plan sum. Variations greater than 5% in dose to the tumor or organs at risk were considered clinically relevant. A two-sided paired t-test was used to evaluate the statistical significance of the dosimetric differences.ResultsThe percent dose difference between plans without tissue heterogeneity corrections to those with corrections resulted in an overall median difference of -3% (range: -15.1% to 9.6%; p < 0.01) for the dose covering 95% of the planning target volume (PTV D95) and was -5.6% (range: -17.3% to 5.4%; p < 0.01) for lung volume receiving ≥20 Gy (lung V20). For 3D-CRT, the median difference for the PTV D95 was -0.1% (range: -4.7% to 9.6%; p = 0.62) and the lung V20 was -4.2% (range: -9.4 to 5.4; p < 0.01). For IMRT, the median difference for the PTV D95 was -10.0% (range: -15.1% to -5.3%; p < 0.01) and the lung V20 was -8.9% (range: -17.3 to -3.5; p < 0.01).ConclusionTraditional planning without tissue heterogeneity corrections results in an overall decrease in the dose delivered to the target compared with those that incorporate tissue heterogeneity corrections. These differences are modest for 3D treatment plans but may result in clinically relevant differences for the IMRT cohort (>5% deviation).

Highlights

  • Lung cancer is the leading cause of cancer-related deaths in the United States for both men and women in 2019

  • This is a retrospective analysis of 35 patients (three-dimensional conformal radiation therapy (3D-CRT), n = 22; intensity-modulated radiation therapy (IMRT), n = 13) with LS-Small cell lung cancer (SCLC) treated with chemoradiotherapy from 2011 to 2017

  • The percent dose difference between plans without tissue heterogeneity corrections to those with corrections resulted in an overall median difference of -3% for the dose covering 95% of the planning target volume (PTV D95) and was -5.6% for lung volume receiving ≥20 Gy

Read more

Summary

Introduction

Lung cancer is the leading cause of cancer-related deaths in the United States for both men and women in 2019. 230,000 new cases of lung cancer are diagnosed each year with an associated mortality rate of nearly 25% [1]. Small cell lung cancer (SCLC) accounts for nearly 15% of all lung cancer cases. The majority of individuals have metastatic disease at presentation and are more commonly referred to as having extensive-stage small cell lung cancer. 30% of patients will be diagnosed with limited-stage small cell lung cancer (LS-SCLC) [2,3,4]. This staging system was defined by the Veterans Administration Lung Group in accordance with whether the disease is confined to one hemithorax and could be adequately encompassed

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call