Abstract

The influences of relative humidity (RH) on the heterogeneous reaction of NO2 with soot were investigated by a coated wall flow tube reactor at ambient pressure. The initial uptake coefficient (γ initial) of NO2 showed a significant decrease with increasing RH from 7 to 70%. The γ initial on "fuel-rich" and "fuel-lean" soot at RH=7% was (2.59±0.20)×10-5 and (5.92±0.34)×10-6, respectively, and it decreased to (5.49±0.83)×10-6 and (7.16±0.73)×10-7 at RH=70%, respectively. Nevertheless, the HONO yields were almost independent of RH, with average values of (72±3)% for the fuel-rich soot and (60±2)% for the fuel-lean soot. The Langmuir-Hinshelwood mechanism was used to demonstrate the negative role of RH in the heterogeneous uptake of NO2 on soot. The species containing nitrogen formed on soot can undergo hydrolysis to produce carboxylic species or alcohols at high RH, accompanied by the release of little gas-phase HONO and NO.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.