Abstract

BackgroundThe relationship of spirometric values to other respiratory and functional parameters in advanced age is not well studied. We assessed this relationship in elderly subjects with either good or poor spirometric parameters to reveal whether different domains of lung function show comparable differences between the two groups.MethodsAmong subjects of the population-based KORA-Age cohort (n = 935, 65-90y; 51% male) two groups were selected from either the lower (LED; n = 51) or the upper (UED; n = 72) end of the FEV1 distribution. All subjects did not have a history of lung disease and were non-smokers at the time of the study. Measurements included spirometry, body plethysmography, diffusing capacity for NO and CO, respiratory pump function and exhaled NO (FeNO). In addition, 6-min walking distance as a functional overall measure, as well as telomere length of blood leukocytes and serum 8-hydroxydeoxyguanosine (8-OHdG) as potential markers of overall biological ageing and stress were determined.ResultsIn the majority of parameters, LED subjects showed significantly impaired values compared to UED subjects. Differences in spirometric parameters, airway resistance and respiratory pump function ranged between 10% and more than 90% in terms of predicted values. In contrast, volume-related CO and NO diffusing capacity showed differences between groups of lower than 5%, while telomere length, 8-OHdG and FeNO were similar. This was reflected in the differences in “functional age” as derived from prediction equations.ConclusionsIn elderly subjects without a history of lung disease differences in spirometric parameters were associated with differences in other lung-mechanical parameters including body plethysmography but not with differences in volume-corrected gas exchange measures. Thus, the concept of a general “lung age” as suggested by the widespread use of this term in connection with spirometry should be considered with caution.

Highlights

  • The relationship of spirometric values to other respiratory and functional parameters in advanced age is not well studied

  • We investigated in subjects of advanced age who were free of lung disease according to their clinical history, whether various functional indices show parallel differences indicative of a general state of the respiratory system that could be related to aging

  • There were no significant differences between upper end (UED) and lower end (LED) subjects regarding age, height and sex

Read more

Summary

Introduction

The relationship of spirometric values to other respiratory and functional parameters in advanced age is not well studied. We investigated in subjects of advanced age who were free of lung disease according to their clinical history, whether various functional indices show parallel differences indicative of a general state of the respiratory system that could be related to aging. For this purpose we analyzed the relationships between forced expiratory volume in 1 s (FEV1), static lung volumes, airway conductance, respiratory pump function, pulmonary gas exchange, exhaled biomarkers, systemic oxidative stress and cell-biological age, as well as general physical capacity. The study population comprised two subgroups of the KORA-Age cohort who had been selected based on their percent predicted values of FEV1 either being at the upper or the lower end of the distribution

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call