Abstract

Objective To investigate the development of the load-bearing capacity of a ceramic-reinforced glass ionomer cement (GIC), stored dry or wet, using Hertzian indentation. Methods GIC discs 2 mm thick and 10 mm in diameter were made (Amalgomer CR, Advanced Healthcare, Tonbridge, Kent, UK), randomly divided into 8 groups and stored at 37 °C in air or artificial saliva (AS) for 1, 7, 30 and 90 days. Discs were tested by loading centrally using a 20 mm diameter hard steel ball while resting freely on a filled-nylon substrate ( E: 10 GPa), at 23 °C in air. The failure load at the first bottom-initiated radial crack was detected acoustically. Results All the failure loads of air-stored specimens were higher than those of AS-stored specimens. The failure load was relatively stable for air-stored specimens but showed a significant decreasing tendency for AS-stored specimens. Significance Zirconia-reinforced GIC is sensitive to moisture. Artificial saliva storage has a detrimental effect on the failure load of ceramic-reinforced GIC that may indicate long-term deterioration in service.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.