Abstract
The purpose of this study was to evaluate CT arteriography (CTA) using an implantable port system in the detection of perfusion abnormalities occurring during hepatic arterial infusion chemotherapy (HAIC). In 51 patients with unresectable primary and metastatic liver tumors, who had implanted port systems for HAIC, CTA examinations through the infusion pump were performed. When perfusion abnormalities were found, selective angiography and/or digital subtraction angiography using the implantable port system were performed to determine the etiology. Forty-nine perfusion abnormalities were detected in 32 patients. Intrahepatic hypoperfusion was found in 24 cases. Of 11 patients in whom correction of the hypoperfusion was attempted, it was successful in 10. Of 13 patients in whom correction was not attempted, 6 patients showed progressive disease in nonperfused areas. Intrahepatic hyperperfusion was found in 14 cases, which showed no subsequent complication. Extrahepatic perfusion was found in 11 cases. We consider CTA to be useful in detecting perfusion abnormalities that may compromise HAIC.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.