Abstract

Plasma concentrations of hepatic glutathione S-transferase (GST) are a more sensitive measure of acute hepatic damage than aminotransferase activity. Plasma GST concentrations have been measured by radioimmunoassay in an open randomised study after halothane or isoflurane anaesthesia. The concentration of GST was significantly increased after anaesthesia in patients who received halothane in 30% oxygen/70% nitrous oxide (n = 37) and in patients who received halothane in 100% oxygen (n = 17). The frequency of abnormal GST concentrations, defined as 4 micrograms/l or more, was 35% and 24%, respectively. GST concentrations usually reached a peak 3-6 h after the end of anaesthesia. In 17 patients who received isoflurane in 30% oxygen/70% nitrous oxide, there was no significant rise in GST concentration and no patient had a concentration above 4 micrograms/l. No patient in any of the groups had a significant increase in alanine aminotransferase. In clinically identical situations, anaesthesia with halothane but not isoflurane leads to demonstrable impairment of hepatocellular integrity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.