Abstract
Very few studies have compared the total hepatic blood flow using the Indocyanine green (ICG) method with the instantaneous electromagnetic flow method under unsteady circulatory conditions. In this study, a hypotensive circulatory state was produced by rapid hemorrhage in 14 dogs. Total hepatic blood flow was measured using the ICG single injection method, comparing it with the electromagnetic flow method. After confirming the validity of the ICG single injection method in measuring total hepatic blood flow in the steady state, the experiment was then carried out using 23 normal healthy dogs. The close correlation between the ICG clearance technique and the electromagnetic values under normal steady state was confirmed. However, after hemorrhage the indirect ICG method estimated only 71% of the simultaneous electromagnetic flow value. It is reasonable to assume that while the electromagnetic method continues to measure the actual total hepatic blood flow in both the steady and unsteady states, the ICG clearance method measures only the functional hepatic blood flow which is reduced due to shunting or impaired hepatocellular function in the unsteady and hypotensive circulatory state.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.