Abstract

BackgroundClinically insignificant hemolytic anemia is occasionally a complication of prosthetic valve replacement. However, hemolysis related to kinked grafts is a very rare complication after central repair for acute aortic dissection.Case presentationA 42-year-old man had undergone replacement of the ascending aorta and a root repair for type A aortic dissection 6 months previously. Laboratory data showed mild hemolysis 5 months later, and he began to complain of fatigue on exertion. The serum hemoglobin level reduced to 8.6 g/dL, and lactate dehydrogenase levels increased to 3071 IU/L with gross change in urine color, indicating hemoglobinuria. We diagnosed mechanical hemolytic anemia caused by a kinked graft and planned a repeat operation. The kinked graft was resected and graft-graft anastomosis was performed. Postoperatively, the clinical course was uneventful, and the hemolytic anemia completely resolved.ConclusionWe herein report a case of hemolytic anemia caused by kinking of the graft 6 months after acute aortic dissection repair. The diagnosis was swiftly made, and the patient was successfully managed with redo surgery.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.