Abstract

Background Bicuspid aortic valve (BAV) is known as the most common congenital anomaly and its complications (ascending aortic aneurysm, dissection) can lead to noticeable morbidity and mortality. There is increasing evidence that, in addition to its genetic background, changes in aortic hemodynamics may play an important role in the development of aortopathy in these patients. Studies have shown that BAV can substantially alter aortic hemodynamics, but it is unclear if the genetic basis can influence aortic properties and 3D blood flow in BAV relatives with normal tricuspid valves. In this study, we evaluated flow dynamics, aorta diameter and geometry in BAV relatives compared to normal volunteers using 4D flow MRI. Methods 15 controls and 3 families with one known BAV case in each family (Figure 1) underwent contrast agent enhanced (BAV relatives: MultiHance, controls: Ablavar) MRI (1.5 or 3T, Siemens, Germany) for the evaluation of ascending aorta (AAo) dimensions, aortic valve morphology, aortic shape, width to height ratio, and aortic 3D blood flow dynamics. To assess valve morphology and global cardiac function, breath-held, ECG-gated time-resolved (CINE) 2D balanced SSFP images were acquired. Aortic blood flow assessment was done using ECG and respiratory-gated CINE 3D phase-contrast MRI with 3D velocity encoding (4D flow) and full volumetric coverage (VENC = 150-250 cm/s, temporal resolution = 38.4-40.0 ms). Net flow and peak velocity were measured at the level of SOV (sinuses of valsalva), AAo (proximal to brachiocephalic trunk), distal aortic arch and descending aorta (DAo, level of left atrium) using commercial software (Ensight, CEI, NC). The presence and severity of helix and vortex flow was assessed by two readers using a defined 3-point grading scale in a blinded manner. Results Vortex and helix flow grading was performed with excellent inter-observer agreement (Cohen’ sk appa, = 0.73). Vortex flow was significantly more frequent in BAV relatives compared to controls (Figure 2, p < 0.001). Specifically, vortex flow was increased in the AAo (p < 0.004) and DAo (p < 0.025). Helix flow and flow parameters were similar in BAV relatives and controls. 47% of all BAV relatives had a different (p < 0.007) aortic shape than the typical round shape of the controls (93.3%). Peak velocity was reduced (p = 0.009) for gothic aortas and more vortices were found in cubic aortas (p < 0.001).

Highlights

  • Bicuspid aortic valve (BAV) is known as the most common congenital anomaly and its complications can lead to noticeable morbidity and mortality

  • Studies have shown that BAV can substantially alter aortic hemodynamics, but it is unclear if the genetic basis can influence aortic properties and 3D blood flow in BAV relatives with normal tricuspid valves

  • We evaluated flow dynamics, aorta diameter and geometry in BAV relatives compared to normal volunteers using 4D flow MRI

Read more

Summary

Introduction

Bicuspid aortic valve (BAV) is known as the most common congenital anomaly and its complications (ascending aortic aneurysm, dissection) can lead to noticeable morbidity and mortality. There is increasing evidence that, in addition to its genetic background, changes in aortic hemodynamics may play an important role in the development of aortopathy in these patients. Studies have shown that BAV can substantially alter aortic hemodynamics, but it is unclear if the genetic basis can influence aortic properties and 3D blood flow in BAV relatives with normal tricuspid valves. We evaluated flow dynamics, aorta diameter and geometry in BAV relatives compared to normal volunteers using 4D flow MRI

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call