Abstract

Robot-assisted laparoscopic radical prostatectomy has gained widespread use. However, circulatory effects in patients subjected to an extreme Trendelenburg position (45°) are not well characterized. We studied 16 patients (ASA physical status I-II) with a mean age of 59 years scheduled for robot-assisted laparoscopic radical prostatectomy (45° head-down tilt, with an intraabdominal pressure of 11-12 mm Hg). Hemodynamics, echocardiography, gas exchange, and ventilation-perfusion distribution were investigated before and during pneumoperitoneum, in the Trendelenburg position and, in 8 of the patients, also after the conclusion of surgery. In the 45° Trendelenburg position, central venous pressure increased almost 3-fold compared with the initial value, with an associated 2-fold increase in mean pulmonary artery pressure and pulmonary capillary wedge pressure (P<0.01). Mean arterial blood pressure increased by 35%. Heart rate, stroke volume, cardiac output, and mixed venous oxygen saturation were unaffected during surgery, as were echocardiographic heart dimensions. After induction of anesthesia, isovolumic relaxation time was prolonged, with no further change during the study. Deceleration time was normal and stable. In the horizontal position after pneumoperitoneum exsufflation, filling pressures and mean arterial blood pressure returned to baseline levels. Pneumoperitoneum reduced lung compliance by 40% (P<0.01). Addition of the Trendelenburg position caused a further decrease (P<0.05). Arterial blood acid-base balance was normal. End-tidal carbon dioxide tension increased whereas arterial carbon dioxide was unaffected with unchanged ventilation settings. Pneumoperitoneum increased PaO2 (P<0.05). Ventilation-perfusion distribution, shunt, and dead space were unaltered during the study. Pneumoperitoneum and 45° Trendelenburg position caused 2- to 3-fold increases in filling pressures, without effects on cardiac performance. Filling pressures were normalized immediately after surgery. Lung compliance was halved. Gas exchange was unaffected. No perioperative cardiovascular complications occurred.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.