Abstract
Objective: To evaluate the hemodynamic alterations during off-pump coronary artery bypass graft surgery to determine the degree of impairment caused and the techniques to rectify them. Design: Prospective, observational cohort study performed from January 2000 through September 2000. Participants: Patients (n = 500) with coronary artery disease undergoing multivessel off-pump coronary artery bypass graft surgery using the Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, MN). Unstable patients with ongoing ischemia were excluded from the study. Interventions: All patients were monitored with radial artery and pulmonary artery catheters and continuous transesophageal echocardiography monitoring with a multiplane transducer. The perioperative requirement of an intracoronary shunt, inotropes, or an intra-aortic balloon pump was noted. The effect of the Trendelenburg position and fluids on hemodynamics was observed. The need for defibrillation and institution of emergency cardiopulmonary bypass were major endpoints to determine the inability of the patient to tolerate displacement of the heart. Measurements and Main Results: Mean patient age was 59.3 ± 11.6 years. There were 204 (40%) patients in the high-risk category; 54 (10.8%) patients had left ventricular ejection fraction <25%. The mean number of grafts was 2.7 ± 0.8. Vertical displacement of the heart to access the lateral and inferior walls decreased the mean arterial pressure by 18 ± 4% (p < 0.01), with a concomitant increase in central venous pressure of 66 ± 18% (p < 0.001). The stroke volume and the cardiac index were reduced by 35.7 ± 11% (p < 0.001) and 45 ± 13% (p < 0.001). On transesophageal echocardiography, there was development of new regional wall motion abnormalities in 59.2% and a decrease in global left ventricular functions in 61.2%. The use of inotropes was highest during anastomosis on the posterior wall—78.4% compared with 21.9% for the anterior wall. An intra-aortic balloon pump was used in 55 (11.2%) patients, and 7 (0.71 %) patients had to be put on emergency CPB. The in-hospital mortality was 1.2%. Conclusion: Most patients had hemodynamic changes easily correctable by fluids and inotropes. Monitoring of left ventricular and right ventricular function by transesophageal echocardiography enhances safety of the procedure and is recommended. The use of the Octopus II tissue stabilizer proved to be a safe and versatile means to stabilize the heart during off-pump coronary artery bypass procedures, especially in high-risk patients. Copyright 2002, Elsevier Science (USA). All rights reserved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Journal of Cardiothoracic and Vascular Anesthesia
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.