Abstract
Measurement of blood flow rate (Qa) is used to monitor arteriovenous fistulas and grafts that are used for hemodialysis blood access. Most Qa measurements use indicator dilution techniques to measure the recirculation that is induced by the reversal of hemodialysis blood lines. R plus the dialysis circuit flow (Qb) allows the calculation of Qa. The principle of needle reversal also can be used with a dialysate urea monitor (e.g., DQM 200 [Gambro]) without injection of diluent; the effect of the reversal on urea concentration is observed. Access blood water flow rate (Qaw) in relation to the effective clearance (K) is found from the urea concentrations in the dialysate with needles in the normal (Cn) and reverse (Cr) positions: K/Qaw = (Cn - Cr)/Cr. Qa is calculated by adjusting Qaw for hematocrit and protein. For testing of this theoretical relationship, 20 patients who were dialyzed on Integra (Hospal) and Centrysystem 3 (Cobe) machines that were fitted with DQM 200 were studied. During each treatment, lines were reversed and Qa was measured by ultrasound velocity dilution (Transonic HD01 monitor); at the same time, Cn and Cr were measured by DQM 200 and K was calculated. K1 was determined from a predialysis blood urea concentration (Cb), initial dialysate urea concentration (Cd), dialysate flow rate (Qd), and the relationship K x Cb = Qd x Cd (K1). K was determined separately from a conductivity step method using Diascan (Hospal) attached to Integra machines only (K2). With the use of K1, 127 comparisons were made; a correlation existed (r = 0.916), although Bland-Altman analysis showed that the dialysate urea method gave a mean value 5.3% +/- 15.3 (+/-SD) higher than that of Transonic (P < 0.001). With the use of K2, there also was a correlation of (r = 0.944; n = 63), and Bland-Altman testing showed an NS difference of +3.5% between the dialysate urea and Transonic methods. Qa can be estimated from on-line dialysate urea measurements that are taken before and after line reversal together with knowledge of K.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Clinical Journal of the American Society of Nephrology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.