Abstract

Patients on maintenance hemodialysis are vulnerable to chloramine toxicity if chloramines are inadequately removed. We report two critically ill patients with acute renal failure who developed methemoglobinemia during hemodialysis in the intensive care unit. During the same period, methemoglobin levels measured from 30 patients in the outpatient dialysis facility were undetectable. Methemoglobin levels normalized when the carbon filtration system of the portable dialysis machine was replaced with a larger unit to remove chloramines more effectively. Causes, treatment, and prevention of chloramine toxicity in patients receiving dialysis in the intensive care unit are discussed. © 2002 by the National Kidney Foundation, Inc.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.