Abstract

Phosphatidylethanol (PEth) forms in erythrocyte membranes after alcohol consumption, offering a persisting biomarker, that is measurable in whole blood, washed erythrocytes and dried blood spots. For a predominantly erythrocyte-restricted analyte, erythrocyte concentrations seem to have most validity in patients who are anemic through alcoholism or other pathologies, despite preparation increasing assay complexity. Differences in specimen preparation alter PEth concentrations for the same patient, meaning that criteria for interpreting PEth results should relate to specimen type, presenting a barrier to achieving harmonization. We therefore tested whether erythrocyte PEth might be validly calculated by hematocrit correction of a whole blood PEth measurement. PEth testing primarily serves to distinguish drinkers from non-drinkers. In choosing between specimen types, it is important to compare their utility in separating those two groups. We therefore processed 281 blood samples from 17 non-drinkers and 61 drinkers, to prepare matched whole blood and washed erythrocyte specimens. These were assayed by liquid chromatography-tandem mass spectrometry and compared in identifying alcohol consumption. The erythrocyte PEth concentration in the whole blood specimens was also calculated by correcting whole blood concentration by the specimen's hematocrit, as an alternative to prepare washed erythrocytes. The hematocrit-corrected erythrocyte concentrations were included in these comparisons. Predictably, this work found that sensitivity was consistently better at the lower cut-off of 8 µg/L than at 20 µg/L. Sensitivities were also higher for washed erythrocytes than whole blood, explained by the lower erythrocyte mass in the same volume of whole blood. Hematocrit-corrected whole blood PEth concentrations correlated with erythrocyte concentrations, except for the four highest values, which did not influence comparative sensitivity. Specificity was 100% for washed erythrocytes, whole blood and hematocrit-corrected whole blood at either cut-off because non-drinkers had undetectable PEth. We conclude that hematocrit correction of whole blood PEth concentrations theoretically provides an alternative to the preparation of washed erythrocytes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.