Abstract

Helium liquefaction with a two-stage 4 K pulse tube cryocooler is introduced in this paper. The helium liquefier has a feature of precooling helium gas to be liquefied by using inefficiency of the second stage regenerator in the pulse tube cryocooler. This process reduces enthalpy of the incoming helium gas when entering the condenser and significantly increases the condensation rate. Numerical analysis predicts the precooling heat load on the second stage regenerator, decreases the PTC second stage cooling capacity by only 11% of the heat actually absorbed into the regenerator. A prototype pulse tube helium liquefier was built, which has two precooling heat exchangers on the first stage cold head and the second stage regenerator. It continuously liquefies helium with a rate of 4.8 l/day under normal pressure while consumes 4.6 kW power input.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.