Abstract

This paper describes the principal design features and performance test results of a three-stage Gifford-McMahon cycle cryocooler by which the authors have achieved no-load temperature of 3.3 K and succeeded in helium liquefaction. The key point of the success is the selection of GdχEr1-χRh compounds as a regenerator material. The refrigeration capacity was 20 mW at 4.2 K and the helium liquefaction rate was 10 cm3/h. This is the first success that a Gifford-McMahon cycle cryocooler has liquefied helium without precooling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.