Abstract

In order to study the key technology and physics of RF driven negative ion source for neutral beam injector in China, the Hefei utility negative ions test equipment with RF source was developed at Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). Its negative ion source can be equipped with single or double RF drivers. There is a plasma expansion chamber with depth of 19 mm and an enhanced filter field. A three electrodes negative ion accelerator was employed to extract and accelerate the negative ions, which are plasma grid, extraction grid and ground grid. And there are several diagnostic tools for the plasma and beam parameters measurement. The characteristics of plasma generation, negative ion production and extraction were studied on the test equipment. The negative ion beam was extracted from the RF driven negative ion source for the first time. The detailed structure and main results are presented in this article.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.