Abstract

The mitigation of the consequences of accidental releases of dangerous toxic and/or flammable cloud is a serious concern in the petro-chemical and gas industries. Nowadays, the water-curtain is recognized as a useful technique to mitigate a heavy gas cloud. The paper presents a research methodology, which has been established and undertaken to quantify the forced dispersion factor provided by a water-curtain with respect to its configuration. The method involves medium-scale field tests, Wind-Gallery tests and numerical simulations. These different approaches are discussed and exemplified by typical results emphasizing the observed concentration reduction due to the water-curtain.