Abstract

ABSTRACTExperiments were performed in two steam/air retorts and one water immersion retort to test the influence of included air on heating rate index (fh) values at the center of thin plastic bricks packaged in retort pouches and processed under various temperature and overpressure conditions. In general, high air overpressures (>80 kPa) allowed up to 30 mL air to be included with no detrimental effect on heating rates; however, even small amounts of entrapped air (<5 mL) degraded heat transfer when processed at low air overpressures (<40 kPa). Processing medium and retort type were important factors in the sensitivity of heating rate to increases of air volumes beyond a threshold value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.