Abstract

A recent study on pool boiling for upward facing square heaters reported two pool boiling regimes depending on the relative importance of buoyancy and surface tension forces. At higher gravity levels and/or with larger heaters when the ratio of heater size Lh (length of a side for a square heater) to capillary length Lc was greater than 2.1, boiling was buoyancy dominated and the heat transfer results were heater size independent. Boiling was surface tension dominated and heat transfer results were heater size dependent when Lh/Lc<2.1 (small heaters and/or low gravity conditions). This paper studies the effects of orientation on the balance between buoyancy and surface tension forces. The threshold value of Lh/Lc for transition between pool boiling regimes was found to be 1.8 for heaters oriented at 45°, 90°, and 135°.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.