The aim of this research is to quantify the influence of a louvered blind in a double-glazed unit during night-time conditions. First, an analytical study of free convection was conducted to obtain a set of correlations for the Nusselt numbers of the cavity. Second, a parametric study was performed to calculate the total heat transfer (convective and long-wave radiative) during night-time conditions. The analysis accounted for aspect ratio, blind thermal conductivity, surface emissivity and slat angle. Using these data, a biquadratic equation was developed to calculate the U-factor of a double-glazed unit with an internal louvered blind in terms of the U-factor of the unit without the blind, slat surface emissivity and slat angle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.