Abstract
AbstractThere are three sections in an evaporator tube; liquid heating, foam and climbing film. A technique is presented for estimating the lengths of these three sections and the overall heat transfer coefficients in each of them.The lower the liquid feed temperature, the longer the liquid heating length. The length of the foam section does not depend on the liquid feed temperature. In these studies it was estimated to be more than half the length of the evaporator tube. Only at the higher liquid feed temperatures was a climbing film found to exist.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.