Abstract

High density polyethylene (HDPE) tube has been successfully utilized in surface water source heat pump (SWSHP) system as a surface water heat exchanger (SWHE). Since the heat transfer coefficient (U value) of the HDPE tube directly affects performance and energy efficiency of SWSHP, this research aims to increase U value of HDPE tube by grooving external surface of conventional 32A HDPE tube to reducing cross sectional volume. The final shape of grooved HDPE tube is similar to that of fin. In order to verify the performance of grooved HDPE tube, the U values of grooved and smooth tube were compared experimentally. According to the results, U value of grooved tube showed approximately 21.5% increase with natural convection and 23.5% with forced convection system than U values obtained from smooth tube. The reason for such increase in U value was found to be the reduction in cross sectional volume of the HDPE tube.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.