Abstract

Heat transfer measurements of flow boiling Carbon Dioxide (CO2) in vertical upward direction have been carried out with a dedicated test facility at the European Organization for Nuclear Research (CERN). The investigation covers saturation temperatures within a range of −25∘C≤Tsat≤+5∘C, mass velocities from 100kgm−2s−1≤G≤450kgm−2s−1 and heat fluxes of 5.3kWm−2 and 11.4kWm−2. The experiments have been conducted in a vertical upward evaporator of 8 mm inner diameter and 8 m length and a database of more than 1900 measurements has been compiled within the present study. The heat transfer mechanism is dominated by the nucleate boiling contribution and dryout is observed as a function of saturation temperature, mass velocity and heat flux. A correlation is proposed to predict the dryout inception within the experimental range where the onset of dryout has been observed. The results suggest that most commonly used heat transfer prediction models underpredict the heat transfer mechanisms of CO2. Moreover, the heat transfer coefficients of CO2 increase in vertical upward direction, compared to the data of horizontal studies. For that reason, a vertical multiplier is suggested to capture the trends of vertical upflow with two existing prediction models.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call