Abstract
In this report, a simple model to predict heat transfer distribution in the high temperature region of spray cooling is developed by focusing on the effect of sensible heat of droplets. In the model, it is assumed that the droplets rebound repeatedly on the surface and heat transfer upon droplet impact is proportional to the sensible heat which heats up the droplets to the saturation temperature. The calculated results are compared with existing experimental results and it is shown that the present model can predict the heat transfer distribution in the high temperature region of spray cooling.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.