Abstract

Heat transfer in a pulsating air flow was studied experimentally in the separation region behind a backward-facing step. The data on distributions of heat transfer coefficient have been obtained. At the distance of more than ten step heights away from the step edge, the heat transfer coefficient in pulsating flow deviated by no more than ±10 % from the steady flow values. Towards the step, heat transfer became more intensive relative to the steady regimes. Immediately beyond the separation edge, flow pulsations led to local twofold enhancement of heat transfer and even higher. In general, heat transfer augmentation in the separation region behind the step reached a maximum (70 %) at the Strouhal number Sh ~ 1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.