Abstract

Heat transfer coefficients h have been measured in two-phase (water—air, water—glass beads) and three-phase (water—air—glass beads) fluidized beds. Experiments were performed over a wide range of liquid and gas flowrates in a 0.24 m diam. column fitted with an axially mounted cylindrical heater. Four solids were employed ranging in size from 0.5 to 5 mm. Typical maximum values of h in the three-phase, liquid—gas, liquid—solid and liquid beds were approximately 4800, 4300, 3800 and 1300 W/m 2K respectively. In the three-phase beds h generally increased with liquid and gas velocity and with particle size. Correlations are presented to calculate h in the different beds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.