Abstract
An experiment was conducted basing on the theory with regards to the surface heat transfer from a heated vertical flat plate in laminar flow of low Reynolds number. The following simple equation was obtained, which may be applied to the Prandtl number ranging from 0.006 to 20, by an approximate treatment. [numerical formula] The symbols used in the above equation are as follows : Nux : local Nusselt number, Rsx : local Reynolds number, Ψ1 : functin of Prandtl number, λ : constant. The simple equation agreed with the experimental results by the air, and the flow was divided into three domains as follows. Grx/Rsx2<0.01, for forced convection. 0.01<Grx/Rsx2<16, for mixed convection. 16<Grx/Rsx2, for free convection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transactions of the Japan Society of Mechanical Engineers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.