Abstract

Application of protrusion rib roughnesses on the absorber plate of solar air heater (SAH) duct can effectively enhance the heat transfer rate irrespective of pressure drop penalty. This paper presents the numerical investigation of SAH duct, roughened with conical protrusion ribs. Effect of relative ribs pitch (6≤p/e≤12) and relative ribs height (0.020≤e/D≤0.044) on Nusselt number and friction factor have been studied for the range of Reynolds number from 4000 to 16,000. Thermal efficiency of roughened duct have been determined using useful energy gain to air and heat losses to environment. The maximum thermal efficiency (η) and efficiency enhancement factor (EEF) are found as 69.8% and 1.346%, respectively. Correlations of friction factor and Nusselt number have also been developed as function of Reynolds number and roughness parameters of conical ribs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.