Abstract

Abstract Heat transfer, flow friction and thermal performance factor characteristics in a tube fitted with delta-winglet twisted tape, using water as working fluid are investigated experimentally. Influences of the oblique delta-winglet twisted tape (O-DWT) and straight delta-winglet twisted tape (S-DWT) arrangements are also described. The experiments are conducted using the tapes with three twist ratios (y/w = 3, 4 and 5) and three depth of wing cut ratios (DR = d/w = 0.11, 0.21 and 0.32) over a Reynolds number range of 3000–27,000 in a uniform wall heat flux tube. The obtained results show that mean Nusselt number and mean friction factor in the tube with the delta-winglet twisted tape increase with decreasing twisted ratio (y/w) and increasing depth of wing cut ratio (DR). It is also observed that the O-DWT is more effective turbulator giving higher heat transfer coefficient than the S-DWT. Over the range considered, Nusselt number, friction factor and thermal performance factor in a tube with the O-DWT are, respectively, 1.04–1.64, 1.09–1.95, and 1.05–1.13 times of those in the tube with typical twisted tape (TT). Empirical correlations for predicting Nusselt number and friction factor have been employed. The predicted data are within ±10% for Nusselt number and ±10% for friction factor.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call