Abstract

An experimental study has been carried out for the heat transfer and friction characteristics for arc shaped roughness element used in solar air heaters. Duct has an aspect ratio (W/H) of 11, relative roughness pitch (p/e) range of 4–16, relative roughness height (e/D) range of 0.027–0.045, Reynolds number (Re) range of 2200–22,000 and arc angle (α) was kept constant at 60°. The effects of Re, relative roughness pitch (p/e) and relative roughness height (e/D) on heat transfer and friction factor have been discussed. The results obtained for Nusselt number and friction factor has been compared with smooth solar air heater to see the enhancement in heat transfer and friction factor and it is found out that considerable enhancement takes place in case of heat transfer as well as in friction factor. Correlations were also developed for Nusselt number and friction factor. Thermo-hydraulic performance parameter is also calculated for the same.