Abstract

This study presents the optimum design of the radial heat sink for light-emitting diode (LED) under natural convection. A radial heat sink with a hollow circular base and a P-shape fin type incorporated with either slots or both slots and dimples was numerically investigated using the ANSYS (Fluent) commercial code, with the aim of achieving better cooling performance at a lower heat sink mass.  The average temperature (Tavg) and mass of the HS for various model designs, namely; Type A (HS with plain fin), Type B (HS with slot) and Type C (HS with both dimples and slot) were compared to select the best configuration. The effect of heat flux (700≤q ̇≤1900)  on average temperature of radial heat sink was investigated. It was found that for all three models, the temperature difference between the HS and the ambient air of the fluid domain linearly increased with heat flux. At q ̇=1900W/m2 , when compared to Type A (HS with plain fins), Type C (HS with slot and dimples) models offered the best cooling performance, followed by Type B where the mass and average temperature of the heat sink is reduced by 13.7% and 5.1%, 8.3% and 1%, respectively.