Abstract

Water–copper is one of the most common combinations of working fluid and heating surface in high-performance cooling systems. Copper is usually selected for its high thermal conductivity and water for its high heat transfer coefficient, especially in the two-phase regime. However, copper tends to suffer oxidation in the presence of water and thus the heat flux performance is affected. In this research, an experimental investigation was conducted using a cooper bare surface as a heating surface under a constant mass flux of 600 kg·m−2·s−1 of deionized water at a subcooled inlet temperature ΔTsub of 70 K under atmospheric pressure conditions on a closed-loop. To confirm the heat transfer deterioration, the experiment was repeated thirteen times. On the flow boiling region after thirteen experiments, the results show an increase in the wall superheat ΔTsat of approximately 26% and a reduction in the heat flux of approximately 200 kW·m−2. On the other hand, the effect of oxidation on the single phase is almost marginal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.