Abstract

This paper presents the detailed heat transfer coefficients over a flat surface with one row of injection holes inclined streamwise at 35° for three blowing ratios (M=0.5–2.0). Three compound angles of 0°, 45°, and 90° with air (D.R.=0.98) and CO2 (D.R.=1.46) as coolants were tested at an elevated free-stream turbulence condition (Tu≈8.5%). The experimental technique involves a liquid crystal coating on the test surface. Two related transient tests obtained detailed heat transfer coefficients and film effectiveness distributions. Heat transfer coefficients increase with increasing blowing ratio for a constant density ratio but decrease with increasing density ratio for a constant blowing ratio. Heat transfer coefficients increase for both coolants over the test surface as the compound angle increases from 0° to 90°. The detailed heat transfer coefficients obtained using the transient liquid crystal technique, particularly in the near hole region, will provide a better understanding of the film cooling process in gas turbine components.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call