Abstract

Experimental heat transfer equipment with a buried tube granular bed was set up for waste heat recovery of flue gas. The effects of flue gas inlet temperature (1096.65–1286.45 K) and cooling water flow rate (2.6–5.1 m3/h) were studied through experiment and computational fluid dynamics’ (CFD) method. On the basis of logarithmic mean temperature difference method, the total heat transfer coefficient of the granular bed was used to characterize its heat transfer performance. Experimental results showed that the waste heat recovery rate of the equipment exceeded 72%. An increase in the cooling water flow rate and inlet gas temperature was beneficial to recovering waste heat. The cooling water flow rate increases from 2.6 m3/h to 5.1 m3/h and the recovery rate of waste heat increases by 1.9%. Moreover, the heat transfer coefficient of the granular bed increased by 4.4% and the inlet gas temperature increased from 1096.65 K to 1286.45 K. The recovery rate of waste heat increased by 1.7% and the heat transfer coefficient of the granular bed rose by 26.6%. Therefore, experimental correlations between the total heat transfer coefficient of a granular bed and the cooling water flow rate and inlet temperature of dusty gas were proposed. The CFD method was used to simulate the heat transfer in the granular bed, and the effect of gas temperature on the heat transfer coefficient of granular bed was studied. Results showed that the relative error was less than 2%.

Highlights

  • Granular beds are extensively used in the metallurgical industry, environmental protection, and other fields given their simple structure, convenient operation, and strong environmental adaptability

  • The total heat transfer coefficient of the granular bed refers to the comprehensive heat transfer coefficient between high-temperature flue gas and cooling water

  • To improve the heat transfer process in the buried tube granular bed heat exchanger, 60 tubes were arranged in a staggered way, for a total of 8

Read more

Summary

Introduction

Granular beds are extensively used in the metallurgical industry, environmental protection, and other fields given their simple structure, convenient operation, and strong environmental adaptability. Nasr et al [1] used air as the working medium to study the influence of filling particle diameter and heat transfer coefficient of the heat transfer process in granular beds. Their results showed that small particles indicate improved heat transfer performance of a granular bed. Cong et al [10] obtained the total heat transfer coefficient through logarithmic mean temperature difference method and conducted an experimental study on the heat transfer of a gas–solid two-phase mixture. Their study utilized a solid corundum ball as the filtration medium and analyzed the influence of dust concentration and flue gas velocity on the bed temperature distribution through a comprehensive heat transfer coefficient of the bed. (CFD) method, and the simulation results were compared with the experimental results

Mathematical Model
Experimental Design
Experiment and Result Analysis
Analysis of Heat Transfer Experimental Results
Influence of Inlet Flue Gas Temperature on Waste Heat Recovery
Variation curves exchange inin the buried tube granular
Influence
Influence of Cooling Water Flow on Waste Heat Recovery
Numerical Simulation and Analysis
Heat Transfer under Different Cooling Water Flow Rates
11. Influence
Findings
Conclusions