Abstract

A heat transfer experimental of vertical out-tube falling film was conducted with different inlet spray density of ammonia-water solution and inlet hot water temperature. The inlet liquid mass concentration was selected as 60% of ammonia. The experiments showed that the overall heat transfer coefficient increases with the increase of inlet spray density and a maximum overall heat transfer coefficient could be obtained in an optimum spray density of ammonia-water solution, ?, between 0.26 and 0.29 kg/ms. The generation of ammonia vapor outside the vertical falling film had a similar trend with the overall heat transfer coefficient basing on different spray density. The effect of hot water temperature difference, ?T, on overall heat transfer coefficient showed that ?T between 10 and 13 K is the optimum temperature difference of the vertical falling film generation

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.