Abstract

Abstract Experiments were carried out to study the heat transfer characteristics of a pair of premixed, laminar, rectangular, butane/air flame jets impinging vertically upon a water-cooled flat plate. The effects of jet-to-jet spacing and the nozzle-to-plate distance on heat transfer were examined. The Reynolds number of the exit flow was 800. The non-dimensional jet-to-jet spacing ranged from 0.9 to 4.1, while the non-dimensional nozzle-to-plate distance varied from 1 to 6. The between-jet interference decreased with increasing jet-to-jet spacing and nozzle-to-plate distance. Both the maximum local and average heat flux occurred at a moderate jet-to-jet spacing of twice effective nozzle diameter, and when the nozzle-to-plate distance was equal to the effective diameter of the nozzle. The heat flux decreased faster along the shorter sides of the slot jets than the longer sides.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call