Abstract

Abstract The experimental work on heat transfer augmentation using a new kind of insert called twisted tape with continuous cut edges is carried out. The work includes the determination of friction factor and Nusselt number for new twisted tape insert having different twist ratios of 3 & 5. The experimental data obtained from plain tube and conventional twisted tape were verified with the standard correlations to ensure the validation of experimental results. The results of new twisted tape of different twist ratios have been compared with the values for the plain tube and tube with conventional twisted tape. In addition, the effects of the new twisted tape insert on the thermal performance factor are also investigated. The results obtained lead to the conclusion that higher heat transfer rates can be achieved using twisted tape inserts with continuous cut edges at the expense of a reasonable pressure drop.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.