Abstract

In this present study, an experimental investigation has been carried out for a roughened double-pass solar air heater. The respective variation in other parameters, such as relative roughness pitch (p/e), relative roughness height (e/Dh), and angle of attack (α), were 5–20, 0.022–0.044, and 30°–75°, respectively. The effect of roughness and operating parameters on Nusselt number (Nu) and friction factor (f) has been determined, and the results are compared with those of a smooth absorber plate; considerable enhancement in both heat transfer and friction factor is noticed. Utilizing these experimental data, correlations for Nusselt number and friction factor correlations were also developed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.