Abstract
An experimental study on heat transfer and fluid flow has been carried out for a swirling round impinging jet. A thermosensitive liquid crystal sheet was used for the heat transfer measurements and the three velocity components were measured with LDV in the stagnation region for cases where the Swirl number Sw = 0.0, 0.22, and 0.45 at the Reynolds number Re = 8100. The formation of recirculation flow due to a swirl near the impinging wall was found to deteriorate the heat transfer coefficient in the stagnation region and results in a more uniform distribution of the Nusselt number with an increasing Swirl number. The heat transfer mechanism of the swirling impinging jet is discussed based on the flow characteristics of the mean velocities and turbulence quantities. © 2005 Wiley Periodicals, Inc. Heat Trans Asian Res, 34(5): 324–335, 2005; Published online in Wiley InterScience (www.interscience. wiley.com). DOI 10.1002/htj.20068
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.