Abstract
The full-field Nusselt number (Nu) distributions and flow fields are presented, respectively, using steady-state infrared thermography (IR) and particle image velocimetry (PIV) in the two-pass parallelogram channels with attached and detached transverse ribs. These square transverse ribs on two opposite channel walls are in-line arranged with rib-height to duct-height ratio of 0.1 and rib pitch-to-height ratio of 10. For the detached ribs, the detached distance between rib and channel wall is 0.38 rib height. With the measurements of Fanning friction factor (f), the thermal performance factors (TPF) for the attached and detached-rib cases are comparatively examined. A set of Nu, f, and TPF with the associated flow measurements at the Reynolds number range of 5000 ≤ Re ≤ 20,000 is selected to disclose the differential heat transfer mechanisms and efficiencies between the attached and detached ribbed channels. Empirical correlations evaluating the area-averaged Nusselt numbers (Nu¯) and f factors are devised to assist the relevant design activities.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.